TOP Current Transformer Manufacturer- Since 1998
PRODUCT CATEGORY

CONTACT US
Qianyao Industrial Zone,Liushi,Yueqing, Zhejiang Province, China 
Tel:  +86-577-62700712
Fax: +86-577-62708776 
Mobile: +86 186 5836 9816
Email: sales@qianweict.com
Msn:

Skype:

  
Product Center > Worldwide CT Showroom         (not for sale) > Germany CT > European Current Transformer
European Current Transformer
European Current Transformer

Manufacturer: MBS AG  
 


Address:'Sulzbach MesswandlerEisbachstraße 51  74429 Sulzbach-Laufen  Germany
Website: www.mbs-ag.com

Tel: +49 7976 9851-0   Fax: +49 7976 9851-90



New CTB current transformers

At the beginning of the year 2010, the MBS AG, ‘Sulzbach Messwandler’ has inaugurated in their product range a new current transformer.
This latest current transformer, type CTB, incorporates not only a higher maximum operating voltage (Um < 1,0 kV) but also an increased isolation test voltage (6 kV Ueff, 1 min., 50 Hz) as well as an increased ambient temperature range (-5 °C < T < +50 °C).
The new CTB’s connection is arranged with a "cage clamp ®".
The production of the new current transformer is in accordance with the technical characteristics corresponding to DIN EN 60044-1, DIN VDE 0414, part 1 and DIN 42600.
UL Certification applied: Certificate Number - 20100426-E336996.
 


undefined 

 

ASR Tube current transformer

Current transformers with circular primary conductor for primary nominal current from 30 A up to 1000 A, secondary nominal currents 5 A, 2 A or 1 A, accuracy classes 0.2, 0.5s, 0.5, 1 and 3, optional with copper tube or snap-on mounting.

 

 undefined 
 

Current transformers with circular primary conductor for primary nominal current from 30 A up to 1000 A, secondary nominal currents 5 A, 2 A or 1 A, accuracy classes 0.2, 0.5s, 0.5, 1 and 3, optional with copper tube or snap-on mounting. 

ASK CTB Plug-in current transformer 
 

Plug-in current transformers for primary nominal currents from 30 A up to 8000 A, secondary nominal current 5 A, 2 A or 1 A, accuracy classes 0.2s, 0.2, 0.5s, 0.5 and 1.
All fixing materials are included in the deliveries. Optional is the supply of the primary bus bar chrome nickel-plated conductors conforming to the bus bar window, inclusive of screws DIN 933, complete with nuts, U-discs and springs for the mounting onto bus bars or similar components.
 

 

 

 see  more

WSK Wound current transformer 
 

Wound current transformers for primary nominal currents from 1 A up to 150 A, secondary nominal current 5 A, 2 A or 1 A, accuracy classes 0.2, 0.5s, 0.5 and 1, with primary winding and primary connector terminals instead of a continuous bus bar.




KBR KBU Split core current transformers
 

Split core current transformers for primary nominal currents from 100 A up to 5000 A, secondary nominal current 5 A, 2 A or 1 A, accuracy classes 0.5 and 1.
The split measuring system facilitates a simple, subsequent installation into already existing panel boards without additional mounting requirements. For the installation the locking mechanism of the current transformer is to be opened and placed around the primary conductor and audible locked, ensuring that the circuit is closed. Once the secondary conductors are connected, the unit is ready for operation.
 




Split core current transformers (KBR/KBU) (7) KSU SUSK Summation current transformer (KSU/SUSK) 
 

Summation current transformers for primary nominal currents of 5 A or 1 A, secondary nominal current 5 A, 2 A or 1 A, accuracy classes 0.2, 0.5 and 1. The numerals following the letters indicate the quantity of how many primary circuits can be connected. Up to 8 connections are possible. 



NH Current transformers for fuse rails (NH)

Current transformers for fuse rails for primary nominal currents from 100 A up to 600 A, secondary nominal current 5 A or 1 A, accuracy class 3.
Secondary connections in excess of 4 mm require jacks for direct mounting onto the contact rail of low voltage high performance fuses with contact knives integrated in the NH-fuse set, according to DIN 43620/1.
NH current transformers are fitted with 2 or 4 tip sockets and can be operated constantly under load.
Idling voltage at secondary primary nominal current 5 A approx. 3-6 V and a secondary nominal current 1 A approx. 13.25 V.
Available in 3 different sizes (NH 1, NH 2, NH 3)

.

SASK Protection plug-in current transformer (SASK) 

Protection plug-in current transformers for primary nominal currents from 50 A up to 2000 A, secondary nominal current 5 A, 2 A or 1 A, protection classes 5P5, 10P5, 5P10 and 10P10.

 


ASRD ASK ASD WSKD Three-phase current transformer set (ASRD/ASK(D)/ASKD/WSKD)

 Three-phase current transformer set, for primary nominal currents from 3 x 50 A up to 3 x 750 A, secondary nominal current 5 A, 2 A or 1 A, accuracy classes 0.2, 0.5s, 0.5 and 1.............see more .....  see see   


 

Easily add us for best service and price:
WhatApp:+86 18658369816   /  skype: skypeadminister   /  linkedin: cn.linkedin.com/in/qianweict

click to other model catalogue:


 

Prev:end Next:end
Copyright © All rights reserved by Qianwei Current Transformer CO.,LTD ©2008-2019   Sitemap